Get a Quote

Product · Technical data

High-Rate Battery, 6-GFMHR Series (12 V)

High-rate 12 V blocks for UPS and switchgear that must ride through short, heavy discharges, 145 W - 750 W.

Choose a model

Specification Pending
Battery type
VRLA gel (AGM)
Nominal voltage
12 V (6 cells)
Capacity range
37 - 210 Ah
Design life
12 years
Cycle use voltage
14.28 - 14.52 V
Standby use voltage
13.38 - 13.62 V

Values are withheld until confirmed by our engineering team.

01Model overview

12 V (6 cells) Nominal voltage
12 years Design life
10 Models in this range
Model 10HR capacity 1HR capacity Internal resistance Max charge current Dimensions
6-GFMHR-145W 37 Ah 20.4 Ah 9.2 mΩ 197 × 166 × 174 mm
6-GFMHR-180W 45 Ah 24.8 Ah 7.5 mΩ 263 × 165 × 170 mm
6-GFMHR-215W 55 Ah 30.25 Ah 6.5 mΩ 263 × 165 × 170 mm
6-GFMHR-250W 65 Ah 35.8 Ah 5.3 mΩ 350 × 167 × 181 mm
6-GFMHR-300W 75 Ah 42.3 Ah 4.8 mΩ 330 × 172 × 215 mm
6-GFMHR-400W 100 Ah 55 Ah 3.5 mΩ 408 × 174 × 210 mm
6-GFMHR-500W 125 Ah 68.8 Ah 3.2 mΩ 483 × 170 × 235 mm
6-GFMHR-600W 150 Ah 82.5 Ah 3.0 mΩ 534 × 206 × 219 mm
6-GFMHR-700W 180 Ah 99 Ah 2.5 mΩ 534 × 206 × 219 mm
6-GFMHR-750W 210 Ah 116 Ah 2.3 mΩ 523 × 239 × 220 mm

Figures are taken from the current AllGrand product brochure. Specifications are indicative and may be revised without notice — confirm with our engineers before ordering.

02Overview

High-rate 12 V blocks for UPS and switchgear that must ride through short, heavy discharges, 145 W – 750 W.

03Key features

  • 12 V
    • Detailed characteristics to be confirmed for this model.
  • High rate
    • Detailed characteristics to be confirmed for this model.
  • UPS
    • Detailed characteristics to be confirmed for this model.
  • Specified against the duty cycle
    • Cell and plate selection matched to the real operating profile.
    • Capacity and autonomy sized to the load, not to a catalogue average.
  • Batch control
    • Incoming material control and in-process inspection on every batch.
    • Traceability from plate casting through to packing.
  • End-of-line testing
    • Electrical testing before packing, with results available on request.

04Specification

Battery type
VRLA gel (AGM)
Nominal voltage
12 V (6 cells)
Capacity range
37 - 210 Ah
Design life
12 years
Cycle use voltage
14.28 - 14.52 V
Standby use voltage
13.38 - 13.62 V
Company certification
ISO 9001 · ISO 14001 · ISO 45001

Figures are taken from the current AllGrand product brochure. Specifications are indicative and may be revised without notice — confirm with our engineers before ordering.

Let's build the right energy solution.

Send us the application, nominal voltage and capacity target. Our engineers will specify the battery and system architecture around it.

WhatsApp