Get a Quote

Product · Technical data

Front Terminal Battery, 6-GFMZ Series (12 V)

Front-terminal 12 V blocks for data centres and telecom cabinets, 45 - 200 Ah, easy rack installation.

Choose a model

Specification Pending
Battery type
VRLA gel (AGM)
Nominal voltage
12 V (6 cells)
Capacity range
45 - 200 Ah
Design life
12 years
Cycle use voltage
14.28 - 14.52 V
Standby use voltage
13.38 - 13.62 V

Values are withheld until confirmed by our engineering team.

01Model overview

12 V (6 cells) Nominal voltage
12 years Design life
6 Models in this range
Model 10HR capacity 1HR capacity Internal resistance Max charge current Dimensions
6-GFMZ-45 45 Ah 24.75 Ah 6.5 mΩ 291 × 106 × 223 mm
6-GFMZ-55 55 Ah 30.25 Ah 6.3 mΩ 291 × 106 × 223 mm
6-GFMZ-100 100 Ah 55 Ah 4.8 mΩ 409 × 110 × 286 mm
6-GFMZ-150 150 Ah 82.5 Ah 4.5 mΩ 551 × 110 × 288 mm
6-GFMZ-180 180 Ah 99 Ah 4.0 mΩ 557 × 125 × 318 mm
6-GFMZ-200 200 Ah 110 Ah 3.8 mΩ 557 × 125 × 318 mm

Figures are taken from the current AllGrand product brochure. Specifications are indicative and may be revised without notice — confirm with our engineers before ordering.

02Overview

Front-terminal 12 V blocks for data centres and telecom cabinets, 45 – 200 Ah, easy rack installation.

03Key features

  • 12 V
    • Detailed characteristics to be confirmed for this model.
  • Front terminal
    • Detailed characteristics to be confirmed for this model.
  • Data centre
    • Detailed characteristics to be confirmed for this model.
  • Specified against the duty cycle
    • Cell and plate selection matched to the real operating profile.
    • Capacity and autonomy sized to the load, not to a catalogue average.
  • Batch control
    • Incoming material control and in-process inspection on every batch.
    • Traceability from plate casting through to packing.
  • End-of-line testing
    • Electrical testing before packing, with results available on request.

04Specification

Battery type
VRLA gel (AGM)
Nominal voltage
12 V (6 cells)
Capacity range
45 - 200 Ah
Design life
12 years
Cycle use voltage
14.28 - 14.52 V
Standby use voltage
13.38 - 13.62 V
Company certification
ISO 9001 · ISO 14001 · ISO 45001

Figures are taken from the current AllGrand product brochure. Specifications are indicative and may be revised without notice — confirm with our engineers before ordering.